Skip to content

EMVA 1288 Characterization

The EMVA 1288 standard (European Machine Vision Association, currently Release 4.0) defines a unified methodology for measuring and reporting image sensor performance. This page summarizes its parameter set and how each item maps to the noise and signal model used elsewhere in this chapter.

EMVA 1288 is structured around a small set of physical inputs and a parameter list that downstream measurements report. The simplification it makes is a linear model: signal is proportional to incident photon number, and noise sources are independent and add in quadrature.

Parameter set

Sensitivity metrics

ParameterSymbolMeaning
Quantum efficiencyη(λ)Probability that an incident photon at λ produces a collected electron
ResponsivityRSlope of the photon-transfer line in DN per photon
Absolute sensitivity thresholdμpminPhoton count at which SNR = 1

The sensitivity threshold is the minimum detectable photon number per pixel and is approximately

μpmin1η(σread+σread2+14)

with σread in electrons.

Noise metrics

ParameterSymbolMeaning
Temporal dark noiseσdRead-noise floor in e RMS at zero exposure
PRNUuPRNUPixel-to-pixel gain non-uniformity (fraction of signal)
Saturation SNRSNRmaxBest achievable SNR before saturation

In the shot-noise-limited regime, SNRmaxμsat where μsat is the saturation signal in electrons.

Capacity metrics

ParameterSymbolMeaning
Saturation capacityμsatMaximum signal in e (full well)
Dynamic rangeDRRatio of μsat to noise floor
Useful bitsbusefulEffective ADC resolution given noise

The useful bits are computed from DR as buseful=log2(DRlinear) and may be lower than the ADC's nominal bit depth when read noise exceeds 1 DN.

Dark current metrics

ParameterSymbolMeaning
Mean dark signal rateμIDark current in e/s at nominal T
Dark current doubling temperatureTdΔT that doubles μI, typically 6–8 °C
DSNUσydarkSpatial standard deviation of dark signal

The dark signal model is μdark(T,t)=μI(T)t. Combined with the Arrhenius dependence from Noise, SNR, and Dynamic Range, this lets the standard report dark current at any operating temperature from a single calibration.

SNR curve and grade reporting

EMVA 1288 expects the SNR-versus-irradiance curve to be reported with:

  • The actual measured curve (limited by read noise at low end, shot noise in the middle, PRNU at the top)
  • The ideal shot-noise-limited reference SNRideal=N

The gap between the two curves quantifies how far the sensor deviates from ideal photon counting and is the most informative summary plot in the standard.

A typical EMVA 1288 report tags each parameter with a quality grade — for example:

  • Excellent — best-in-class performance for that metric
  • Typical — common production range
  • Below typical — may limit specific applications

The grading is not part of the linear model itself; it is a convention for quickly flagging which parameter is the bottleneck for a given imaging task.

Boundary with adjacent pages

Adjacent pageDifference
Noise, SNR, and Dynamic RangeDefines the underlying noise model used by EMVA 1288. Read it first if you are not already familiar with PRNU/DSNU, FWC, and the PTC.
Quantum EfficiencyEMVA 1288 reports a single integrated η per spectral band; this page covers the spectrally and spatially resolved definition.
Signal ChainThe signal-chain page converts QE into camera-system signal predictions; EMVA 1288 instead reports sensor-only metrics at fixed irradiance.

Browser simulator

  • EMVA 1288 Dashboard — explore the full parameter set interactively, with the actual-vs-ideal SNR curve and quality grades.